Quick Service for Full HMI Parts Replacement
Home / All / for Siemens / Siemens SIMATIC S7-300 /

6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case

6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case

6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case
6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case6AG1321-1FF10-7AA0 Siemens SIMATIC S7 300 Plastic Case
CategoriesSiemens SIMATIC S7-300
BrandVICPAS
Model6AG1321-1FF10-7AA0
BrandSiemens
Warranty365 Days
Product LineSiemens SIMATIC S7-300 Plastic Housing
SupplySiemens SIMATIC SM 321 digital input module
Siemens S7-3006AG1321-1FF10-7AA0
Model6AG1 321-1FF10-7AA0
Number6AG13211FF107AA0
FOB portGuangzhou, Shenzhen, Hongkong
Terms of PaymentWestern Union, MoneyGram, T/T, Paypal, PayPal, Credit Card
Download DOCpdf icon
Update TimeApr 25,2024
Detail Information

6AG1321-1FF10-7AA0 Siemens SIMATIC S7-300 Module Housing Repair Replacement


6AG1321-1FF10-7AA0 Siemens SIMATIC S7-300 SM 321 digital input modules Plastic Shell Repair Replacement

Digital output module SM 321; DO 16 x UC 24/48 V; (6AG1321-1FF10-7AA0 Enclosure) Properties
Performance features of the SM 321; DO 16 x UC24/48 V digital output module:
● 16 electrically isolated semiconductor relay outputs
● Electrical isolation between channels of 120 V
● Switching characteristics: RDS ON is typically 0.25 Ohm, and RDS OFF is typically greater than 100 GOhm
● Designed for load voltages up to 48 V AC or DC, no minimum load voltage
● Designed for output loads up to 0.5 A, no minimum load current
● Outputs are fully independent and support any wiring configuration
● Set substitution values or "Hold last values" can be programmed at the outputs for CPU STOP.
● The module supports diagnostics of programming errors and of external power failure
● Suitable for AC solenoids, actuators, motor starters, FHP motors and signal lamps
● Supports parameter reassignment in RUN


S7-300 6AG13211FF107AA0 SM 321 digital input modules HMI Case systems are intended for stationary use in locations protected against the weather. The operating conditions surpass the requirements of DIN IEC 60721-3-3.
 Class 3M3 (mechanical requirements)
 Class 3K3 (climatic requirements)


VICPAS supply 6AG1321-1FF10-7AA0 Siemens S7 300 Simatic Module Plastic Case Cover Replacement Part. All of them with VICPAS 365 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the 6AG1321-1FF10-7AA0 Siemens SIMATIC SM 321 digital input modules Case Parts.

Part Number : 6AG1321-1FF10-7AA0
Atmospheric pressure: 1080 to 660 hPa
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Product Line: Siemens Simatic S7-300
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Safety isolation: SELV circuit
Power consumption: 57 W
Power loss: Typ. 9 W
Efficiency: 84 %


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6AG1195-7KF00-2XA0 Siemens S7-300 safety protector HMI Case Replacement In Stock
6AG1321-1BH02-2AA0 Siemens SIPLUS S7-300 Plastic Case SM 321 Replacement Available Now
6AG1321-1CH20-2AA0 SIMATIC S7 300 SM 321 Plastic Shell Repair Part In Stock
6AG1321-1FF01-2AA0 Siemens S7-300 SM 321 Housing Enclosure Repair Available Now
6AG1321-1FF10-7AA0 Siemens S7-300 SM 321 Plastic Shell Replacement In Stock
6AG1321-1FH00-7AA0 Siemens S7-300 SM 321 Plastic Case Replacement In Stock
6AG1321-7BH01-2AB0 SIMATIC S7 300 SM321 HMI Enclosure Replacement In Stock
6AG1321-7TH00-4AB0 SIMATIC S7 300 Plastic Case SM 321 Replacement Available Now
6AG1322-1BF01-2XB0 Siemens S7-300 SM 322 Housing Repair Replacement Available Now
6AG1322-1BH01-2AA0 Siemens S7-300 Plastic Shell SM 322 Repair In Stock
6AG1322-1CF00-7AA0 SIMATIC S7 300 HMI Case SM 322 Replacement Available Now
6AG1322-1FF01-7AA0 Siemens S7-300 SM 322 Housing Replacement In Stock
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6AG13211FF012AA0 Datasheet
  • 6AG13211FF107AA0 Datasheet
  • 6AG13211FH007AA0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: When should I use expansion devices?

    Answer: You can use EDs if the number of CU slots is insufficient for your application.
    When using EDs, you might require further power supply modules in addition to the extra module racks and interface modules (IM). When using interface modules, you must ensure compatibility of the partner stations.


    Question: In which situations should I backup the operating system?

    Answer: For example, you should backup the operating system of your system CPU if you want to replace it with a standby CPU and ensure that the operating system is identical in the replacement CPU.
    It is also highly recommended to generate a backup copy of the operating system for emergency situations.


    Question: What is the 6AG1321-1FF10-7AA0 Siemens Simatic S7-300 Module Housing parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Common misspellings: 

    6AG1321-1FF10-AA0
    AG1321-1FF10-7AA0
    6AG1321-1FF107-AA0
    bAG1321-1FF10-7AA0
    6AG1321-1FF10--7AA0
    Review
    • Loading...
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?