Quick Service for Full HMI Parts Replacement
Home / All / for Siemens / Siemens SIMATIC S7-300 /

Siemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI Case

Siemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI Case

Siemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI Case
Siemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI CaseSiemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI CaseSiemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI CaseSiemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI CaseSiemens SIMATIC S7 300 6AG1322-5HF00-4AB0 HMI Case
CategoriesSiemens SIMATIC S7-300
BrandVICPAS
Model6AG1322-5HF00-4AB0
BrandSiemens
Warranty365 Days
Product LineSiemens SIMATIC S7-300 Plastic Housing
SupplySiemens SIMATIC S7 300 SM 322 digital outputmodule
Siemens S7-3006AG1322-5HF00-4AB0
Model6AG1 322-5HF00-4AB0
Number6AG13225HF004AB0
FOB portGuangzhou, Shenzhen, Hongkong
Terms of PaymentWestern Union, MoneyGram, T/T, Paypal, PayPal, Credit Card
Download DOCpdf icon
Update TimeMar 29,2024
Detail Information

6AG1322-5HF00-4AB0 Siemens SIMATIC S7-300 Module Housing Repair Replacement


6AG1322-5HF00-4AB0 Siemens SIMATIC S7-300 SM 322 digital output modules Plastic Shell Repair Replacement

S7-300 6AG13225HF004AB0 SM 322 digital output modules HMI Case systems are intended for stationary use in locations protected against the weather. The operating conditions surpass the requirements of DIN IEC 60721-3-3.
 Class 3M3 (mechanical requirements)
 Class 3K3 (climatic requirements)


Programmable digital IO module SM 322; DI 8/DO 8 x DC 24 V/0.5 A (6AG1322-5HF00-4AB0 Plastic Shell) Properties
Properties of SM 322; DI 8/DO 8 x DC 24 V/0.5 A:
• 8 digital inputs and 8 individually configurable inputs or outputs, isolated in groups of 16
• Rated input voltage 24 V DC
• Inputs suitable for switches and 2-/3-/4-wire proximity switches (BEROs)
• Output current 0.5 A
• Rated load voltage 24 V DC
• Outputs capable of driving solenoid valves, DC contactors and indicator lights
• Dynamic change of parameters in RUN (CiR-compatible), separately at each channel.
• Readback of outputs.


VICPAS supply 6AG1322-5HF00-4AB0 Siemens S7 300 Simatic Module Plastic Case Cover Replacement Part. All of them with VICPAS 365 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the 6AG1322-5HF00-4AB0 Siemens SIMATIC SM 322 digital output modules Case Parts.

Part Number : 6AG1322-5HF00-4AB0
Atmospheric pressure: 1080 to 660 hPa
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Product Line: Siemens Simatic S7-300
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Safety isolation: SELV circuit
Power consumption: 57 W
Power loss: Typ. 9 W
Efficiency: 84 %


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6AG1322-1FH00-7AA0 Siemens S7-300 SM 322 Plastic Case Replacement In Stock
6AG1322-1HF10-2AA0 SIMATIC S7 300 SM322 HMI Enclosure Replacement In Stock
6AG1322-1HH01-2AA0 SIMATIC S7 300 Plastic Case SM 322 Replacement Available Now
6AG1322-5FF00-4AB0 Siemens S7-300 SM 322 Housing Repair Replacement Available Now
6AG1322-5HF00-4AB0 Siemens S7-300 Plastic Shell SM 322 Repair In Stock
6AG1322-8BF00-2AB0 SIMATIC S7 300 HMI Case SM 322 Replacement Available Now
6AG1323-1BH01-2AA0 Siemens S7-300 SM 323 Housing Replacement In Stock
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6AG13225FF004AB0 Datasheet
  • 6AG13225HF004AB0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: Putting a New 6AG1322-5HF00-4AB0 Plastic Case Cover Body Module into Service

    Answer: Proceed as follows to put the new module into service:
    1. Open the front panel.
    2. Reinstall the front connector.
    3. Close the front panel.
    4. Switch the load voltage back on.
    5. Set the CPU to RUN mode again.
    Putting a New 6AG1322-5HF00-4AB0 Plastic Case Cover Body Module into Service


    Question: When should I use expansion devices?

    Answer: You can use EDs if the number of CU slots is insufficient for your application.
    When using EDs, you might require further power supply modules in addition to the extra module racks and interface modules (IM). When using interface modules, you must ensure compatibility of the partner stations.


    Common misspellings: 

    6AG1322-5HF00-4A0
    AG1322-5HF00-4AB0
    6AG1322-5FH00-4AB0
    6AG1322-5HF00-4A80
    6AAG1322-5HF00-4AB0
    Review
    • Loading...
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?